# Marine Master HI97105 Multiparameter Photometer (OPEN BOX)

- Link: https://aquaticfarms.com/products/marine-master-hi97105-multiparameter-photometer-open-box/
- Published: 2026-10-25T10:15:53-04:00
- Author: 

**Accurately check pH, Alkalinity, Calcium, Low Range and High Range Nitrate, Ultra
Low Range Nitrite, and Ultra Low Range Phosphate with one single, compact multiparameter
tester!**

 

**All-In-One Testing with Precise Results for Reef Tanks**
The HI97105 Marine Master
Photometer is a waterproof tester that combines accuracy and ease of use into one
simple, portable design. Its advanced, lab-quality optical system ensures accurate
readings while its user-friendly design and built-in tutorials make it perfect for
marine scientists and aquarium hobbyists alike.

 * Precise and advanced LED optical system
 * No warm up time needed before taking a measurement
 * Waterproof and floating IP67 meter design
 * CAL Check validation and calibration
 * Consolidates testing needs into one unit
 * Includes auto-data logging features to easily record water testing results
 * On-screen tutorial mode guides users step-by-step through the measurement process
 * Option to select measurement location for better tracking consistency
 * Auto shut-off
 * Rugged carrying case included

 

**Precise Laboratory Testing, Simplified**
The Marine Master Photometer comes equipped
with user-friendly on-screen tutorials and animations to help guide you through 
every step of setup, calibration, and testing. You can easily access this Tutorial
Mode at any stage of the setup or measurement process by tapping the dedicated Help
key.

**Smart Energy Use**
When the battery level is below 10%, a warning symbol will 
blink to indicate low battery condition. When low battery power may affect your 
results, the meter will shut down to avoid erroneous readings caused by low battery
level. In order to preserve battery life, the Marine Master has an Auto-Off feature
that will automatically power down the device after 15 minutes of inactivity.

 

**Auto Data Logging**
The Marine Master will automatically log your results, so 
there is no need to worry if you’ve missed recording a measurement. The last 50 
measurements can be instantly viewed using the Log Recall Menu.

 

**CAL Check Validation**
Hanna’s exclusive CAL Check feature provides a stress-free,
straightforward way to ensure your photometer is working properly. Simply insert
the certified CAL Check standards and let your meter guide you through validation.
If your photometer is out of specification for any reason, simply calibrate to your
standard.

 

**Advanced Optical System**
The Marine Master has an advanced optical system that
uses a Light Emitting Diode (LED) and a narrow band interference filter that allows
for accurate and repeatable readings. The internal reference system of the photometer
compensates for any drifts due to power fluctuations or ambient temperature changes,
providing a stable source of light for the blank (zero) measurement and sample measurement.
Improved optical filters ensure greater wavelength accuracy and allow a brighter,
stronger signal to be received. A focusing lens collects all of the light that exits
the cuvette, eliminating errors from cuvette imperfections and scratches. The end
result is highly reliable lab-grade readings in the palm of your hand.

 

**Durable & Portable Design**
Designed to withstand the knocks, drops, and spills
of real life, the new IP67 body ensures top performance in any environment. Internal
optics are sealed from outside dust, dirt, and water. The meter also floats, so 
you can easily retrieve it if you drop it in water. This photometer uses an exclusive
positive‑locking system to ensure that the cuvettes are placed into the holder in
the same position for accurate readings every time.

The Marine Master also fits comfortably in your hand for on-the-go testing. The 
supplied AA batteries provide life for more than 800 measurements, and its backlit
LCD display can provide readings from any angle, day or night. Everything you need
for testing comes neatly stored in the provided durable carrying-case for added 
convenience.

 

**What’s Included?**
1x HI97105C Photometer1x HI780-25 Marine pH reagent (30mL)1x
HI772-26 Marine Alkalinity reagent (30mL)1x HI7581U Marine Calcium reagent A (30mL)
1x HI7582 Marine Calcium reagent B starter kit (reagent for 25 tests)1x HI782-25
Marine Nitrate High Range starter kit (reagent for 25 tests)1x HI764-25 Marine Nitrite
Ultra Low Range starter kit (reagent for 25 tests)1x HI774-25 Marine Phosphate Ultra
Low Range starter kit (reagent for 25 tests)2x Sample cuvettes and caps2x 1mL Graduated
syringes with tips1x Mini Pipette with tip2x 3mL Pasteur pipettes3x 1.5V AA alkaline
batteries1x Cleaning cloth for wiping cuvettes1x Scissors1x Instrument quality certificate1x
Instruction manual1x Hard carrying case

  |

#### **Testing Parameter**

  |

#### **Specifications**

  |  
 |

#### **Marine⏎ Alkalinity

  |  Range |  0.0 to 20.0 dkH
0 to 357 ppm (as CaCO3) |  
 |  Resolution |  0.1 dkH |  
 |  Accuracy |  ±0.3 dKH ±5 % of reading at 25 °C ±5 ppm ±5 % of reading at 25 °C |  
 |  Method |  Colorimetric Method – The reaction causes a distinctive range of colors from yellow to greenish blue to develop |  
 |

#### **Marine⏎ Calcium

  |  Range |  200 to 600 ppm |  
 |  Resolution |  1 ppm |  
 |  Accuracy |  ±6 % of reading at 25 °C |  
 |  Method |  Adaptation of the Zincon Method |  
 |

#### **Marine⏎ Nitrate

  |  Range |  0.00 to 5.00 ppm (as NO3¯)
0.0 to 75.0 ppm (as NO3¯) |  
 |  Resolution |  0.01 ppm 0.1 ppm |  
 |  Accuracy |  0 to 200 ppb (as NO2¯-N) |  
 |  Method |  Adaptation of the Zincon Method Colorimetric Method The reaction between nitrate and the reagent causes a pink/violet tint in the sample. |  
 |

#### **Marine⏎ Nitrite ULR

  |  Range |  0 to 200 ppb (as NO2¯-N) |  
 |  Resolution |  1 ppb |  
 |  Accuracy |  ±10 ppb ±4 % of reading at 25 °C |  
 |  Method |  Adaptation of the EPA Diazotization Method 354.1 – The reaction between nitrite and the reagent causes a pink tint in the sample. |  
 |

#### **Marine⏎ pH

  |  Range |  6.3 to 8.6 pH |  
 |  Resolution |  0.1 pH |  
 |  Accuracy |  ±0.2 pH of reading at 25 °C |  
 |  Method |  Colorimetric Adaptation of the Phenol Red Method |  
 |

#### **Marine⏎ Phosphate LR

  |  Range |  0.00 to 0.90 ppm |  
 |  Resolution |  0.01 ppm |  
 |  Accuracy |  ±0.02 ppm ±5 % of reading at 25 °C |  
 |  Method |  Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method – The reaction between phosphate and the reagent causes a blue tint in the sample. |  
 |

#### **General**

  |  Light Source |  Light emitting diode |  
 |  Light Detector |  Silicon photocell |  
 |  Bandpass Filter Bandwidth |  8 nm |  
 |  Bandpass Filter Wavelength Accuracy |  ±1.0 nm |  
 |  Logging |  200 readings |  
 |  Power Supply |  1.5 V AA Alkaline (3 pcs.) |  
 |  Battery Life |  > 800 measurements (without backlight) |  
 |  Auto-off |  After 15 minutes of inactivity (30 minutes before a READ measurement) |  
 |  Environment |  0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable |  
 |  Dimensions |  142.5 x 102.5 x 50.5 mm (5.6″ x 4.0″ x 2.0″) |  
 |  Weight |  380 g (13.4 oz.); with batteries |  
 |  Warranty |  2 years |