# Pro Calcium/Magnesium Test Kit (OPEN BOX)

- Link: https://aquaticfarms.com/products/pro-calcium-magnesium-test-kit-open-box/
- Published: 2026-10-25T14:23:28-04:00
- Author: 

**High Precision Calcium & Magnesium Tests for Saltwater Aquariums**

Calcium and Magnesium are two of the top key components in seawater and having them
at the proper levels is imperative to proper coral growth. As corals grow then will
consume calcium to build the calcium carbonate skeleton, while magnesium will be
consumed much slower, but is mainly used to keep calcium and carbonate from precipitating
out at the levels required by a saltwater aquarium. The high-resolution calcium 
and magnesium tests include everything required to make repeatable and reliable 
results. Each test only takes a few minutes and regularly testing your calcium and
magnesium will really let you know how your coral is growing, and allow you to fix
any issues before they become a larger problem. 

 

**Calcium:**

 * Up to 50 Tests
 * Measurement Range – 300 – 498 ppm
 * Accuracy – 4 ppm

 

**Magnesium:**

 * Up to 50 Tests
 * Measurement Range – 820 – 1800 ppm
 * Accuracy – 20 ppm

 

**Note**: The calcium concentration is determined first, and then the magnesium 
concentration is determined using the same sample.

 

**Instructions:**

**Determining the calcium level:**

 1.  Shake the bottles before use!
 2.  Rinse out both glass cuvettes with tap water and then several times with aquarium
     water.
 3.  Fill each glass cuvette with exactly 5 ml of aquarium water using the dosing syringe.
     Put one of the two water samples aside as a reference.
 4.  Place a clean dropper tip onto the 1 ml dosing syringe with red lettering and 
     draw out reagent A up to the 20 mark on the syringe (corresponds to 0.5 ml). Empty
     the entire amount into the cuvette with the analysis sample.
 5.  Close the glass cuvette using the stopper and briefly swirl the solution.
 6.  Then mix reagent B (powder) with the measuring spoon and add 1 level measuring
     spoon of reagent B to the glass cuvette containing the analysis sample. Swirl 
     the cuvette carefully until the powder has dissolved. The water sample will turn
     light-blue.
 7.  Place another clean dropper tip onto the 1 ml dosing syringe with black lettering
     and draw out 1 ml of reagent C.
 8.  Now add reagent C from the syringe to the analysis sample drop by drop until the
     light-blue solution becomes colorless. Swirl the cuvette after each new drop. 
     To assist in detecting the color change, take the comparison sample (the second
     cuvette you prepared at point 3) on a white surface and look into both cuvettes
     from above when they are sitting side by side. You can stop adding drops when 
     the color change is complete and there is no difference between the analysis sample
     and the comparison sample.
 9.  The residual volume of reagent C in the syringe shows the calcium concentration
     CCa in mg/l (ppm) that can be determined using table I.
 10. Example: If the lower side of the syringe plunger is at 0.46 ml following titration,
     then the residual volume of reagent C is 0.46 ml. The calcium concentration in
     the sample is: Ca = 392 mg/l.
 11. The residual volume of reagent C in the syringe can be put back into bottle C.

 

**Determining the magnesium level: **_Continue from calcium instructions_

 1. Place the third clean dropper tip onto the 1 ml dosing syringe with the green plunger
    and draw out 1 ml of reagent D.
 2. Add approx. 0.4 ml of reagent D into the water sample. The water sample will turn
    light-blue again.
 3. Now add the remaining reagent D from the syringe to the water sample drop by drop
    until the light-blue solution becomes colorless*. Swirl the cuvette after each 
    new drop. To assist in detecting the color change, take the comparison sample (
    the second cuvette you prepared at point 3) on a white surface again and look into
    both cuvettes from above when they are sitting side by side.
 4. The residual volume of reagent D in the syringe shows the magnesium concentration
    CMg in mg/l (ppm) that can be determined using table II.
 5. Example: If the lower side of the syringe plunger is at 0.35 ml following titration,
    then the residual volume of reagent C is 0.35 ml. The magnesium concentration in
    the sample is Mg = 1300 mg/l (ppm).
 6. The residual volume of reagent D in the syringe can be put back into bottle D. 
    Rinse out the glass cuvettes, dosing syringes and dropper tips thoroughly with 
    tap water and allow to dry before using them again.

* Note: If the color change from light-blue to colorless is difficult to detect,
we recommend to carry out the measurement under a bright light source which is similar
to daylight.

 

**What’s Included?**

1x Reagent A

1x Reagent B

1x Reagent C

1x Reagent D

2x Test Vials

3x 1mL Syringes

1x 5mL Syringe

1x Measuring Spoon

3x Syringe Tips

1x Instruction Set