# Water Saver Upgrade Kit

- Link: https://aquaticfarms.com/products/water-saver-upgrade-kit/
- Published: 2026-10-25T09:09:50-04:00
- Author: 

**Why does BRS recommend this?**

Water Saving Upgrade Kits are probably our most recommended RODI upgrade. If you
have proper pressure (65+ PSI) we highly recommend installing the kit, because it
will produce water twice as fast as a standard 75 GPD or 100 GPD membrane while 
cutting the amount of wastewater in half.

The BRS 150 GPD or 200 GPD Water Saver Upgrade Kit will increase the production 
of any BRS 75 GPD reverse osmosis system to 150 GPD or 100 GPD RO membrane up to
200 GPD without having to use any additional water. With the installation of this
kit water production will increase from approximately three gallons per hour to 
six gallons per hour! It does require 65psi or more into the first membrane in order
to function properly and be efficient. If your home’s water pressure is less then
the recommended PSI do not worry, adding a booster pump is simple and only takes
a couple of minutes.

 

**Compatible with:**

150 GPD Water Saver Upgrade – All BRS 75 GPD RO/DI Systems

200 GPD Water Saver Upgrade – All BRS 100 GPD RO/DI Systems

 

**Recommended Conditions:**

 * Minimum Water Pressure – 65 PSI
 * Max Water Pressure – 90 PSI
 * Recommended Water Temperature – 77°F
 * Recommended Max TDS – <300ppm

 

Water pressure can be increased by adding a booster pump before your RO/DI system
if a pressure increase is required. Low pressure will cause slow production of product
water, with excess production of wastewater. Pressure over 90 PSI may cause damage
to the RO/DI units filters and components.

 

Recommended Flow Restrictor for 75 GPD RO Systems – 550mL/min

Recommended Flow Restrictor for 100 GPD RO Systems – 800mL/min

 

**What’s Included?**

 * Dow RO Membrane
 * 2x 2.5″ x 2.5″ membrane clips
 * 2x 1/8″ x ¼” 90-degree elbows
 * 1/8″ x ¼” 90° check valve
 * RO membrane housing*
 * ¼” tube splitter
 * 5 Feet of Red, White, Blue and Black RO Line

_*The included 90-degree elbows and check-valve come pre-installed on the RO membrane
housing._

 

DOW Filmtec 75 GPD Membranes have a 96% – 99% typical stabilized salt rejection 
rate that can be reproduced through the following conditions;

 * Source Water Pressure – 50 PSI / Membrane
 * Source Water Temperature – 77°F
 * Source Water TDS – 250ppm Softened Tap Water
 * Recovery – 15%
 * Minimum Salt Rejection – 96%

DOW Filmtec 100 GPD Membranes have a 96% – 98% typical stabilized salt rejection
rate that can be reproduced through the following conditions;

 * Source Water Pressure – 50 PSI / Membrane
 * Source Water Temperature – 77°F
 * Source Water TDS – 500ppm Softened Tap Water
 * Recovery – 15%
 * Minimum Salt Rejection – 96%

 

*High TDS – Source water with high TDS we do not recommend using the 150 GPD water
saving upgrade kit. If used you may experience increased DI consumption. The system
will work as intended increasing filtered water production rate and decreasing the
amount of waste water, but the overall amount of TDS that comes out of the system
may be slightly higher than a single membrane system. Because of that your DI consumption
will increase. We do recommend using two DI canisters for 150 GPD systems.

**\*\***Drinking Water RO Systems – When filling up the pressure tank will increase
the back pressure, in turn will take longer to fill and increase the waste water
produced by the RO system. We highly recommend a permeate pump for these applications
to minimize waste water.